How Often to Calibrate Winery CO2 Monitors

We recommend calibrating winery CO2 Monitors twice a year, or more often if the manufacturer calls for it, with bump tests between calibrations. Fermentation fills cellars and Tank rooms with CO2, and a monitor that drifts can miss a dangerous level or alarm when nothing is wrong.

Serving Sonoma and Napa counties

Lewis Mechanical service truck at a mechanical installation

Calibration and bump testing are different

A bump test exposes the sensor to CO2 to confirm it responds and sets off its alarms. A calibration checks the reading against a certified reference gas and adjusts it.

What a calibration covers

Each sensor is checked against a certified reference gas, zero and span are adjusted when needed, and we confirm that the alarms and any ventilation tied to the monitor respond. The results are recorded so you have them for your files.

When to calibrate

Before harvest is the most important time, since fermentation is when CO2 levels run highest. A second calibration later in the year keeps drift in check. Add a calibration after a monitor is moved, repaired or exposed to very high levels.

Signs a monitor needs service

Frequent alarms with no clear cause, readings that differ between two monitors in the same room, a failed bump test, or fault codes. If a monitor alarms, treat it as real first and follow your site safety procedure.

When to replace a monitor

Replace it when it cannot pass calibration, keeps faulting or is no longer supported by the manufacturer. Older monitors can be retrofitted with current models.